Browse all practice questions for the North Carolina Fireground Operations 8 Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

North Carolina Fireground Operations 8 Practice Test course image
How Transitional Fire Attack Connects Exterior and Interior OperationsWhich type of attack blends offensive, exterior, and interior components?Reverse hose lay: why the attack line goes from the fire toward the hydrant for effective water deliveryIn a reverse hose lay, the initial attack line is laid from the fire location toward the water source. True or false?Understanding how adjustable-gallonage fog nozzles let you select among several flow settings on the firegroundWhich nozzle design allows selecting among several flow settings?Understanding supply line operations: water moves from the source to the attack engine on the firegroundSupply line operations refer to delivering water from which source to which?Understanding the automatic adjusting fog nozzle and how it maintains steady flow as pressure changesWhich nozzle type is described as automatically adjusting the opening to maintain a range of flows depending on nozzle pressure?Understanding the clapper mechanism: how a one-way check valve keeps water flowing forward in firefighting pipingA mechanical device installed within a piping system that allows water to flow in only one direction.Understanding the hose jacket: a quick, field-ready fix for leaking firefighting hosesA device that is placed over a leaking section of hose to stop a leak is known as aWhat is the attack engine in North Carolina fireground operations, and why does it matter?The attack engine is the engine from which the attack lines have been pulled. True or false?Why the accordion hose load isn’t recommended for large-diameter hoses like LDH on the firegroundThe accordion hose load is not recommended for which hose, because it tends to collapse when placed on its side?
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is the stated purpose of using a piercing nozzle?
  • The term for water delivered to the fire through the handline is which of the following?
  • An adjustable-gallonage fog nozzle describes how it operates. True or false?
  • Which nozzle produces fine droplets of water that absorb heat more quickly than a solid column?
  • A device for use in applications requiring special water discharge patterns, directional spray, or other unusual discharge characteristics.
  • Which term describes a hose with two layers of woven fibers?
  • Which hose component is identified as preventing water from leaking?
  • What GPM range can a 1 1/2 inch hose discharge?
  • A nozzle with a rated discharge of less than 350 gpm (1325 L/min).
  • The blank hose lay is most often used by the first arriving attack engine company at the scene of the fire to establish a water supply line
  • Which nozzle is used to make a hole in automobile sheet metal?
  • The three groups of nozzles are low volume, master stream, and which other type?
  • Which device allows water flow in only one direction within a piping system?
  • What device allows the firefighter at the nozzle to start or stop the flow of water?
  • Blank hose lines are intended for immediate use as attack lines. What term describes these lines?
  • Attack lines can be either multiple jacket or what other construction?
  • Which technique is used to deploy hose from a hose bed and advance the line over a relatively short distance?
  • Which coupling must be threaded together between ends?
  • This hose load is accomplished by placing the hose around the perimeter of the hose bed in a U-shape
  • Which hose is used on the suction side to supply water?
  • A master stream appliance can discharge what GPM?
  • What term describes a stream produced by an adjustable nozzle to provide a straight column of water?
  • Which statement about defensive operations is correct?
  • What is the term for a device that allows fire hose couplings to be safely interconnected with couplings of different sizes or threads?
  • A wye is a device used to?
  • Where along a hose line do changes in direction or openings occur?
  • A short section of hose used to supply water to the suction side of the pump
  • What is a water curtain nozzle used to do?
  • The length of the hose span is based on which factor?
  • Which term refers to a set GPM-rated nozzle output regardless of pressure?
  • For which hose roll is the straight roll or storage roll the correct description?
  • In a reverse hose lay, the supply hose is pulled from which location on the supply engine and connected to which side of the attack engine pump?
  • Which hose is described as lightweight and collapsible and is commonly used in forestry operations?
  • During a reverse hose lay, which location is the supply hose pulled from on the supply engine and connected to on the attack engine?
  • Which nozzle is commonly used to produce high-volume streams in deck gun operations?
  • Describe the split hose lay configuration.
  • Attack hose must be tested annually at a pressure of at least how many psi?
  • When loading fire hose, a short fold close to the coupling is known as a
  • Which hose is intended to be used at pressures up to 185 psi?
  • A booster hose is generally considered to flow how many gpm?
  • In a forward hose lay, where does the supply line originate and terminate?
  • What is the primary benefit of using a blank hydrant valve in a hydrant supply line?
  • Which size is most commonly used for attack lines?
  • Which hose load is best suited for residential fires and described as a triple layer load
  • Which nozzle pattern produces less air movement and maintains the thermal layering better?
  • The last step of a Minuteman hose load includes flat loading the rest of the hose, and then placing the blank coupling to the blank of the hose bed.
  • Forward hose lay is best described as which of the following?
  • What GPM range does a 3 inch large diameter hose (LDH) flow?
  • Which device is used to split a single hose into two separate lines?
  • Which technique is used to deploy hose from the bed and advance the line over a short distance?
  • Places along a hose line where the hose is changing direction, turning a corner, or going through a doorway are known as
  • Which term refers to a hardware component used to connect fire hoses to control or convey water, excluding nozzles?
  • Bresnan distributor nozzles are used to fight fires in
  • When loading fire hose a short fold close to the coupling is known as a
  • Booster hose should not be used for which types of fires?
  • True or False: the forward hose lay is most often used by the second arriving engine company at the scene of a fire.
  • Which hose load is described as a U-shaped perimeter wrap for bed efficiency?
  • A fog stream nozzle produces?
  • Firefighters can add hose to the discharge end of the hose if the nozzle is a
  • The 1 3/4 inch hose can flow in what GPM range?
  • A hose constructed with two layers of woven fibers.
  • Which type of nozzles flow 40 GPM or less?
  • Which hose type is designed to move water between a pressurized water source and the pump that supplies attack lines?
  • A lightweight, collapsible hose that comes in 3/4 inch, 1 inch, and 1 1/2 inch diameters is commonly called what?
  • Which nozzle type is described as delivering a preset flow at the rated discharge pressure?
  • A smooth bore nozzle operates at blank PSI.
  • A fire department connection on a building enables pumping water into which two systems?
  • Which nozzle spreads water in a wide pattern as it is lowered through a hole into the cellar?
  • A small, compact roll that can be easily carried by a single firefighter is called what?
  • Attack hose must be tested annually at a pressure of at least how many psi?
  • As a guideline, sprinkler systems should be fed at 150 psi unless more specific information is available.
  • The straight hose lay is also known as which term?
  • The forward hose lay is most often used by the
  • Booster hose is especially suited for attacking vehicle fires. True or false?
  • Which device is mounted on an elevated device to deliver large volumes of water from above?
  • A 50-foot length of 2 1/2 inch dry hose weighs about how many pounds?
  • The triple layer hose load is folded back onto itself to reduce the overall length to what fraction before loading the hose in the bed?
  • A smooth bore nozzle extinguishes a fire with?
  • Which nozzle type operates at 50 psi?
  • A Siamese appliance can be used to split one larger hose into two smaller hoses. True or false?
  • Which device is used to cover a leaking hose section to stop the leak?
  • Which hose load is the easiest to implement and suitable for any size of attack or supply hose?
  • What type of hydrant valve allows immediate charging of the supply hose from the hydrant while permitting a second engine to connect later to provide pump pressure?
  • What type of coupling requires a male and a female fitting screwed together?
  • The triple-layer hose load reduces the overall length to what fraction before loading into the bed?
  • Pre-connected hose lines are used for
  • What term describes a nozzle component that is a smooth tube and accepts interchangeable tips to deliver a solid column of water?
  • The end of the hose bed closest to the tail board is known as the
  • A type of fire nozzle that can be used to add extra hose to the discharge end of the attack line is known as a
  • The split hose bed is used when one long hose line is needed. Which statement about the split hose bed is correct?
  • The notch on the outside of a lug indicating the first thread position on a hose coupling is called what?
  • To perform an interior attack and attack line is usually advanced in how many stages?
  • An adjustable-gallonage fog nozzle can have options of flowing 60, 95, or 125 gpm. True or false?
  • A piece of hardware (excluding nozzles) generally intended for connection to fire hose to control or convey water. (NFPA 1962)
  • Which statement accurately describes the reverse hose lay?
  • Which material is listed as a potential target for a piercing nozzle to create a hole behind surfaces to extinguish fires?
  • A hose lay that is used where hose must be laid in two different directions is known as the
  • Soft sleeve hose is most often used for
  • What term describes delivering water from a hydrant or static source to an attack engine?
  • True or False: If a hose line has to be advanced up a ladder, it should be done before the line is charged.
  • A 1 3/4 inch hand line is generally considered to flow how many GPM?
  • A fire department connection (FDC) is provided so that
  • Threaded hose couplings are used on most hoses up to what diameter?
  • When using this hose roll, both couplings are on the outside of the roll. This hose roll is called what?
  • Which type of hose operates at a higher pressure, supply or attack?
  • The objective of moving hose is to move as much hose as possible. True or false?
  • The 1 1/2 inch hose can flow in what GPM range?
  • The tips on a smooth bore nozzle are designed to be what?
  • Discharging 1 gallon of water in 100 cubic feet of involved interior space can extinguish a fire in how many seconds?
  • Which factor primarily determines the hose span length?
  • Which nozzle can be used to add extra hose to the discharge end of the attack line?
  • Soft sleeve hose is used to draft water from a static water source. True or false?
  • Which nozzle is used on deck guns, portable monitors, and ladder pipes?
  • What is the GPM range for a 1 3/4 inch hose?
  • Which hose role is used for general transportation of hose and rack storage?
  • Booster hose flows in the range of how many gallons per minute?
  • A 50 foot length of dry 2 1/2 inch hose weighs about how many pounds?
  • A type of fire attack that is a combination of offensive, exterior, and interior operations is known as
  • In transporting water from hydrant to suction side, which hose type is typically used?
  • Pre-connected hose lines are used for
  • The minute man hose load is designed to do what?
  • What term describes a nozzle device that is a smooth tube to deliver a solid column of water with interchangeable tips?
  • The objective of laying supply hose is to deliver water from a water supply source to a
  • What are the hoses used to discharge water from an attack engine onto the fire called?
  • Which nozzle type can deliver a wide range of flows and uses a spring-loaded piston to adjust the opening, with a typical operating range of about 90 to 225 GPM?
  • Which type of hose role forms its own carrying loop?
  • Which hose is designed to move water between a pressurized water source and a pump that supplies attack lines?
  • The forward hose lay is most often used by which engine company at the scene of a fire?
  • What is the typical discharge for a 2-1/2 inch handline?
  • In a split hose lay, which describes the active pattern?
  • A breakaway type nozzle can be?
  • Forward hose lay is also referred to as which term?
  • A 2-1/2-inch handline hose is generally considered to flow
  • What term describes the notch on a hose coupling used to indicate the first thread position?
  • A nozzle that delivers a set number of gallons per minute (liters per minute) as per the nozzle's design, no matter what pressure is applied to the nozzle.
  • What term describes a solid column of water?
  • NFPA recommends that a fire pumper carry at least how many feet of 2 1/2 inch or larger supply hose?
  • What does a fixed gallonage fog nozzle deliver?
  • Which hose load allows a single firefighter to flake out the necessary amount of hose from the shoulder while advancing toward the fire, reducing the need to maneuver hose around obstacles?
  • A type of hose carry used to transport full lengths of hose over a longer distance than is practical to drag is known as the
  • When advancing attack lines from the attack engine to the door, the hose should be flaked out in which pattern?
  • Streams of water or extinguishing agents.
  • The Siamese appliance is primarily used to join two hoses into one larger hose. True or false?
  • What is a cellar nozzle primarily used for?
  • Which term describes hose lines that are ready for immediate attack use?
  • Which nozzle splits water into fine droplets?
  • The term for a hose load that is designed to support rapid deployment of a long line is the
  • A type of hose load suited for departments that generally respond to fires in on- or two-story single family dwellings is the
  • The most commonly used attack lines are the
  • Which statement best describes a booster hose?
  • When commanded to advance the hose, what should be your number one priority?
  • This hose load is performed with the hose placed on its edge and laid side to side and the hose bed?
  • This hose load is used when one long hose line is needed
  • Threaded hose couplings are used on most hoses up to what diameter?
  • A smooth bore nozzle has blank tips.
  • Which pattern is described as a serpentine layout used to lay supply hose to an entry point?
  • What is the function of a hose clamp?
  • Attack lines can be either multiple jacket or rubber covered construction. Which option listed below is an acceptable construction for attack lines?
  • Which hose roll has both couplings on the outside of the roll?
  • A nozzle mounted on the end of an aerial device that is capable of delivering large amounts of water into a fire or exposed building from an elevated position.
  • What is the name of the hose lay where the supply engine stops close to the attack engine and the supply hose is connected to the suction side of the attack engine’s pump?
  • A booster hose is usually carried on a hose reel that holds 150 to 200 feet of rubber hose. What type of hose is this described as?
  • The delivery of water from an attack engine to the handline, which discharges the water onto the fire, is called what?
  • Ideally a hose line crew consists of at least three members at the nozzle and a fourth at the door. Which option reflects this standard?
  • What hose component prevents water from leaking out of the hose?
  • Attack lines are used for offensive, defensive, and which other evolution?
  • A defensive attack is conducted from the exterior of the building.
  • A construction consisting of a combination of two separately woven reinforcements (double jacket) or two or more reinforcements interwoven. (NFPA 1962)
  • Which nozzle allows the operator to select a desired flow from several settings?
  • The three basic hose loads for supply hose are the
  • Which statement best describes the attack engine?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy